Regulatory CE MDR 2017/745 Standard
Quality ISO 13485 Certified System
Compliance FDA 510(k) US Market Cleared
Facility GMP Audit Production Safety
Sourcing Process
01
Add to Quote
Select specs & add items to list
02
Submit Details
Fill in your specific requirements
03
Get Offer
Receive official quote within 24h
Wound Care · Non-Adherent Dressing
Non-Adherent Dressing Pad
Perforated film non-adherent wound contact layer — prevents pad adhesion to granulating tissue during dressing changes. Absorbent viscose/cotton core with perforated polyester film on wound-contact face(s). Sterile and non-sterile. One-sided and two-sided variants available.
ISO 13485 CE MDR 2017/745 Class Is (Sterile) Latex-Free
3 typesPerf. film / paraffin / silicone
1 or 2Non-adherent faces — specify
SAL 10⁻⁶Sterile — EO or gamma
Types Available
Three Non-Adherent Dressing Types
Most widely procured
Perforated Film
Viscose or cotton absorbent core bonded to perforated polyester film on one or both wound-contact faces. The perforated film creates a physical barrier preventing gauze fibres from contacting the wound. Exudate passes through to the absorbent core.
Best for: General ward, post-op wound care, first aid kits, IV site coverage, dressing changes.
Burns / grafts
Paraffin-Impregnated
Woven cotton gauze saturated with white soft paraffin (BP minimum ≥175 g/m²). Paraffin lubricates the wound contact surface, preventing fibre adhesion and providing a semi-moist wound environment. Same as vaseline gauze / tulle gras.
Best for: Partial-thickness burns, skin graft donor sites, granulating wounds.
Fragile / high-care
Silicone Mesh
Soft silicone coated on polyamide or polyester mesh. Silicone bonds to surrounding skin to hold the dressing but does not adhere to the moist wound surface — the most atraumatic mechanism available. Higher cost tier.
Best for: Burns, skin grafts, blistering wounds, paediatric, fragile elderly skin.
Kingphar supplies the perforated film type
Kingphar's non-adherent pad is the perforated film format — the most widely procured type for clinical wards and first aid. For paraffin-impregnated (vaseline gauze), see our Vaseline Gauze product page.
Product Features
Why Kingphar Non-Adherent Pad
🩹
Perforated Film Contact Surface
Perforated polyester film wound-contact face creates a physical barrier between the absorbent core and wound tissue. Prevents gauze fibres from embedding in granulating wound bed — atraumatic dressing removal.
💧
Absorbent Viscose/Cotton Core
Soft viscose/cotton blend absorbent core manages light to moderate exudate. Fluid passes through the perforated film into the core away from the wound surface — keeping the contact zone drier.
↔
One-Sided & Two-Sided Options
One-sided (film on wound-contact face only) and two-sided (film on both faces) variants available. Two-sided pads reduce application error risk — no defined wound-contact orientation required. Specify at order stage.
✅
Sterile — EO or Gamma
EO sterilized (ISO 11135) or gamma sterilized (ISO 11137), SAL 10⁻⁶. Individual peel-open sterile packaging per ISO 11607. Non-sterile bulk pack also available for community settings.
🌍
CE Class Is — MDR 2017/745
Sterile non-adherent pads are Class Is under EU MDR 2017/745 — notified body involvement for sterility aspect. CE certificate available. SFDA registration support for GCC/Saudi Arabia supply.
📐
Standard Sizes
5×5 cm, 7.5×10 cm, 10×10 cm, 10×20 cm. Custom sizes and OEM packaging available on request. All sizes available in sterile individually packed and non-sterile bulk formats.
Critical Procurement Note
Always specify: one-sided or two-sided — it is not a minor detail
One-sided non-adherent pads have the perforated film on one face only. If applied film-side out (absorbent core facing wound), the non-adherent property is completely lost — the pad behaves as plain gauze and adheres to the wound. Two-sided pads can be applied either way and reduce this application error risk. For wards with variable staff experience, two-sided pads are lower risk. Specify which type is required — "non-adherent pad" alone does not define this.
Technical Specifications
Product Specification Reference
ParameterSpecificationNotes
Non-adherent mechanismPerforated polyester film — physical barrier between core and woundFilm prevents gauze fibres contacting wound bed
Absorbent core materialViscose/cotton blend or 100% viscoseSoft, high absorbency; fluid wicks through film perforations
Film materialPerforated polyester (PE) filmSmooth, low-friction wound contact surface
Number of film facesOne-sided or two-sided — specify at orderTwo-sided preferred for reduced application error risk
Standard sizes5×5 cm / 7.5×10 cm / 10×10 cm / 10×20 cmCustom sizes available
Sterile presentationEO (ISO 11135) or gamma (ISO 11137) · SAL 10⁻⁶ISO 11607 peel-open packaging
Non-sterile presentationBulk packFor chronic wound management in community settings
Latex contentLatex-freeWritten declaration available on request
Shelf lifeMinimum 3 years from manufacture in sealed packagingStore ≤25°C, away from direct light
RegulatoryCE (EU MDR 2017/745 Class I non-sterile / Class Is sterile) · ISO 13485 · FDA registeredSFDA registration support for GCC supply
Sterile vs Non-Sterile Selection
When Each Presentation Is Appropriate
PresentationAppropriate forNot appropriate for
Sterile (individually packed)All acute wounds; burns; surgical incisions; traumatic lacerations; immunocompromised patients; wounds with exposed subcutaneous tissueRarely — only community chronic wound management with clinical governance approval
Non-sterile (bulk)Chronic wound management with qualified clinician oversight and risk assessment supporting non-sterile techniqueAny acute wound; burns; surgical sites; paediatric wounds; immunocompromised patients
Clinical Applications
Indicated Uses
Minor cuts and abrasions Post-operative wound coverage Granulating chronic wounds Leg ulcer contact layer Pressure injury (low exudate) First aid kit component Under compression bandaging Secondary layer over primary wound contact
Non-adherent pad requires a secondary absorbent dressing
The perforated film non-adherent pad is a wound contact layer only — it has limited or no standalone absorbency. A secondary absorbent dressing (gauze pad, ABD pad, foam dressing) must be placed over it to manage exudate. See our Non-Adherent Dressing Types Guide for complete clinical selection guidance.
📦
Custom sizes, one/two-sided, OEM packaging & Arabic labeling for GCC
SFDA registration support and Arabic-labeled packaging available for Saudi Arabia and GCC institutional supply.
Request Quote

Request samples or bulk quote

ISO 13485 · CE MDR 2017/745 Class Is · EO/gamma sterile · Latex-free · SFDA registration support

Frequently Asked Questions

Quick solution center of gravity

Pre-Purchase

  • We contronl everthing from the raw material to the finished product.Not only can reduce cost but also can grasp the quality
  • Aprofessional manufacturer of gauze, non-woven, cotton and mask  related products with more than 30 years experiences.
  • Customized production can be made according to customer requirements
  • Our certificate,product related all kinds of documents are complete,and do certification experience
  • We export over 100 countries like USA, GERMANY,POLAND,can gibe the xustomer certain reference opinion.
  • Our annual export can be up to CHINA TOP 10
  • Commerce department double white list
  • Professional OEM manufacturer for 30 years First 500 China National Business Credit Enterprises Market covers over 60 countries and regions Service available 24*7,solve your problem at any time

We can provide OEM/ODM services. We have a professional design and production team, that can
produce according to your requirements.

Please contact our custom service to advise your detail request,we will offer some sample for free,
you only need to pay the postage charge. If you already play orders,we will send free samples by our account

Always a pre-production sample before mass production;
Always final Inspection before shipment;

Post-Purchase

We accept FOB, CIF, etc. You can choose the one which is the most convenient or cost effective for you.

Normally 5 day after receiving your payment, but it can be negotiated based on order quantity.

We work with TNT, FedEX, UPS, EMS, DHL to supply you with the best, fastest and safest courier services. It will take about
3-10 days.

Step 1: Confirm the order details (design/art-work, material, quantity, size etc)
Step 2: Pay the deposit
Step 3: Start production
Step 4: Finish production and quality checking
Step 5: Arrange the balance
Step 6:Ship out goods and provide tracking number
Step 7: Receive the goods
Step 8: Give feedback (in order to improve our production and service)

We ensure the quality of the products, and in case of misfortune, we will replace the defective products free of charge according to the quantity of the order

Size

4x4m, 6x4m, 8x4m, 10x4m, 12x4m, 15x4m

Yards

1"x4.1, 2"x4.1, 3"x4.1, 4"x4.1, 6"x4.1